TGA-50 Series - 規格
TGA-50 Series 熱重分析儀
TGA-50
Temperature range: Room temperature to 1000°C/Room temperature to 1500°C (H-type)
Measurement range: ±20, ±200 mg (50-type)
Measurement range: ±20, ±200, ±2000 mg (51-type)
Maximum sample weight: 1 g (including wind bag)/10 g (including wind bag, 51-type)
Temperature range |
Ambient to |
---|---|
Weight measuring range |
20mg, 200mg |
Readability |
0.001mg |
Sample mass |
1 g including tare |
Programmable heating rate |
0.1°C/hour to 99.9°C/min |
Hold time |
0 to 999min, 0 to 999hour |
Temperature program format |
99 steps maximum |
Temperature program file |
up to 100 files |
Cooling method |
Air-cooled |
Signal output |
Analog and digital |
Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
Dimensions |
W173xD550xH500mm |
Power supply |
AC100V, 120V, 220V, 240V, 500VA, 50/60Hz |
TGA-50H
Temperature range |
Ambient to |
---|---|
Weight measuring range |
20mg, 200mg |
Readability |
0.001mg |
Sample mass |
1 g including tare |
Programmable heating rate |
0.1°C/hour to 50.0°C/min |
Hold time |
0 to 999min, 0 to 999hour |
Temperature program format |
99 steps maximum |
Temperature program file |
up to 100 files |
Cooling method |
Air-cooled |
Signal output |
Analog and digital |
Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
Dimensions |
W173xD550xH500mm |
Power supply |
AC100V, 120V, 220V, 240V, 1.2kVA, 50/60Hz |
TGA-51
Temperature range |
Ambient to |
---|---|
Weight measuring range |
20mg, 200mg, 2g |
Readability |
0.001mg |
Sample mass |
10g including tare |
Programmable heating rate |
0.1°C/hour to 99.9°C/min |
Hold time |
0 to 999min, 0 to 999hour |
Temperature program format |
99 steps maximum |
Temperature program file |
up to 100 files |
Cooling method |
Air-cooled |
Signal output |
Analog and digital |
Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
Dimensions |
W173xD600xH540mm |
Power supply |
AC100V, 120V, 220V, 240V, 1kVA, 50/60Hz |
TGA-51H
Temperature range |
Ambient to |
---|---|
Weight measuring range |
20mg, 200mg, 2g |
Readability |
0.001mg |
Sample mass |
10g including tare |
Programmable heating rate |
0.1°C/hour to 50.0°C/min |
Hold time |
0 to 999min, 0 to 999hour |
Temperature program format |
99 steps maximum |
Temperature program file |
up to 100 files |
Cooling method |
Air-cooled |
Signal output |
Analog and digital |
Atmosphere control |
Built-in gas flowmeter (250ml/min maximum) |
Dimensions |
W173xD600xH540mm |
Power supply |
AC100V, 120V, 220V, 240V, 1.5kVA, 50/60Hz |